| echolink |

|
Your advantages
INAT echolink is a Serial Ethernet converter. With echolink, devices without network adapter are able to communicate via network. Echolink supports a wide range of serial protocols. Therefore echolink is much more than a simple data converter. It supports complex applications such as PLC programming or process data visualisation.
Application examples
• Features
• Technical Details
• Accessories
• Highlights
|
|
Features
- Visualization, Measurement data logging, Statistics etc.
- Programming of Simatic S7 / S5 / 505 via LAN and WAN (with VCOM no Softnet* required)
- Remote maintenance of the S7 / S5 / 505 via LAN and WAN
- Ethernet interface for Simatic S5 (AG 90U, 95U, 100U, 115U, 135U, 150U, 155U) via PG port
- Ethernet interface for Simatic S7 (S7-200, S7-300, S7-400) via MPI / PPI port
- Modbus RTU (serial) to Modbus on TCP converter
- Active data transfer between PLCs without programming (echoactive)
- Integration of older systems and devices without Ethernet interface into the network
- Fetch / Write communication with S5 PLCs without handling blocks
- Webserver functionality to realize small visualization projects: Visualization without PHP, ActiveX, Perl, Applets et al. only with HTML
- Optional: Integrated switch to connect other network nodes
- Ethernet interface for Honeywell / Klöckner-Möller IPC controllers via CIM port (ABC protocol)
|
Technical Details
|
- Including VCOM for Programming via Ethernet
- Note: A connector power pack is not included in the delivery. If necessary order it separately
| Ethernet Interface: | 1 x RJ45, 10 / 100 Mbps | | Transport Protocols: | TCP/IP, ISO on TCP (RFC1006), TCP/IP with PLC Header, ISO (H1) | | Applications Protocols | S7 Protokoll, S5-AP, Modbus on TCP, Send / Receive (Raw/ Socket) | | Serial Interfaces: | 1 up to 5 serial interfaces: - RS232, - RS485, - TTY(20mA), - MPI Ordering according to requirements. | | Serial Protocols | AS511 (S5-PG), 3964(R), RK512, Modbus RTU, MPI, PPI, Telnet, optional: ABC (IPC 620 PLCs) | | Power Supply: | 24 V DC, ca. 0,2 to 0,6 A | | Dimensions[in mm]: | H = 131, W = 110, D = 111 | | | Order Numbers: | | echolink basic | 200-6500-01 | | Serial protocol for IPC PLCs | 200-6560-01 |
|
Accessories
|
Interface modules Connector power pack 24 V DC Connection cable RS232 - AG TTY Connection cable echolink TTY - AG TTY Converter cable USB - RS232
|
Highlights
|

Protocol Diversity
- S7 PLCs with MPI/PPI interface ==> with MPI onboard no MPI adapter is required
- S5 PLCs and programming devices
- all devices with RS232/422/485 interface e.g. Scales, Scanner
- Klöckner-Moeller IPC-620 PLCs
Decodes Protocols up to Layer 7
- Conventional Serial Ethernet Converters master only protocols from layer 1 up to layer 4 of the ISO / OSI reference model. Communication is restricted to the transport layer i.e. transfer of raw data (layer 4 communication, Send / Receive)
- In addition to the transport protocols, echolink supports application protocols. Protocol conversion of all seven layers of the ISO / OSI reference model is possible.
- As these "higher-level" protocols are supported, complex applications become possible: process data visualisation, communication between different controller worlds (Siemens, Schneider etc) or programming.
Echoactive Function: Data transfer between PLCs without changing the program
- A distinction is drawn between active and passive job types: active writing of data to the partner station and active fetching of data from the partner station are active job types as well as Send / Receive jobs.
- What kind of jobs are possible depends primarily on the used protocol. With certain protocols only passive jobs are possible (e.g. S5 PLC with AS511 protocol: PLC is able to receive data and to provide data, but the PLC is not able to send data actively or to fetch data from another PLC)
- With the function echoactive, devices, that are - in consequence to their protocol - not able to execute active jobs, receive this possibilty.
- Echolink is monitoring specific data-values in the PLC. When the values change, then the echolink is fetching the data from the PLC and is sending them across the network to the specified communication partner.
- WITHOUT CHANGING THE PLC PROGRAM
Programming
- Programming the S7/S5 is possible via Ethernet with S7/S5 for Windows as well as with STEP* 5 / STEP* 7.
- With VCOM, included in the range of delivery, Softnet* is no longer required.
- Programming AEG PLCs (A 120 / A 150) via LAN and WAN
Visualisation
- Visualisation, Measurement data logging, Statistics etc via LAN and WAN
Communication between PLCs
- Communication between PLCs via LAN and WAN.
- Communication between two PLCs serially connected to echolink
Application examples
Sofnet, Step, Simatic are registered trademarks of the Siemens AG.
|
| Back |
|